The authors report a separate real-robot evaluation on Franka Research 3.
A full LeRobot π₀.₅ fine-tune for four bimanual tasks across six dexterous hands. It shifts both wrist positions to the hand-to-arm mounting face, recomputes normalization statistics, uses three cameras, and supplies the step-20,000 weights.
View full model descriptionPaper / report unconfirmed
Official introductory materials are recorded; no version-specific paper or technical report has been verified.
Last checked: 2026-11-25
Source publication date: 2026-11-25
Source publication date: 2026-11-25
SourceVerified on · 2026-11-26
| File | Access | Weights license |
|---|---|---|
| π₀.₅ · DexVerse Cross-Hand Bimanual (Wrist Mount) · 20k | Access | Weights license unknown |
SourceVerified on · 2026-11-26
Available weights or code do not establish plug-and-play robot compatibility. Check the required configuration, data and interfaces in the source documentation.
Each wrist position is referenced to the hand-to-arm mounting face. Rotate each hand's offset into the original reference frame and subtract it from wrist xyz at indices 0–2 on the right and 31–33 on the left. The left side uses the right offset with the sign of its canonical wrist-local Z component flipped. The rot6d values are unchanged. Quantile statistics were recomputed for indices 0–8 and 31–39. The external frame's origin and axis directions are unconfirmed.
horizon 10 · quantiles
Third-party fine-tune
Fine-tuned from: π₀ · π₀.₅ ↗
LeRobot 0.4.4 PI05Policy trained on 1,200 episodes and 605,812 frames. Training covers OpenFlatFolder, SlideUtilityKnife, BimanualLiftTray and BimanualLiftCarton with Allegro, Inspire, LEAP, Shadow, Sharpa and Wuji. Inputs include task text, base and left/right wrist RGB, and a 62-dimensional state. All three 480×640 images are resized with padding to 224×224. Action chunks span 10 steps. Quantile-normalized state and action vectors each use 31 values for the right hand followed by 31 for the left.
Each wrist position is referenced to the hand-to-arm mounting face. Rotate each hand's offset into the original reference frame and subtract it from wrist xyz at indices 0–2 on the right and 31–33 on the left. The left side uses the right offset with the sign of its canonical wrist-local Z component flipped. The rot6d values are unchanged. Quantile statistics were recomputed for indices 0–8 and 31–39. The external frame's origin and axis directions are unconfirmed.
Physical-robot results for the listed tasks and hands remain unverified for this checkpoint. The bundle provides weights, configuration, preprocessor, postprocessor and tokenizer for inference. Optimizer and training state are absent. Point the preprocessor tokenizer path at the bundled paligemma_tokenizer_hf/. Keep the safetensors state files referenced by the preprocessor and postprocessor JSON for normalization and inverse normalization. The published configuration places the model and preprocessor on CUDA and moves the postprocessed action back to CPU.