π₀.₅ · DexVerse Cross-Hand Single-Arm (Wrist Mount)

Third-party fine-tune
Papers and technical reports

A full LeRobot π₀.₅ fine-tune for single-arm dexterous manipulation across six hands and four tasks. It moves the wrist pose origin to the arm mounting face, recomputes normalization for the first nine state and action dimensions, and provides the step-20,000 weights.

View full model description

Papers and technical reports

Paper / report unconfirmed

Official introductory materials are recorded; no version-specific paper or technical report has been verified.

Last checked: 2026-11-25

How to access and use

Public code resources
Public access
Model files
Public access

Training / fine-tuning code

Access
Public access

SourceVerified on · 2026-11-25

Model files

Model files
π₀.₅ · DexVerse Cross-Hand Single-Arm (Wrist Mount) · 20kAccessWeights license
unknown
Release information

SourceVerified on · 2026-11-25

Checks before deployment

Training coverage does not establish physical-robot validation. The release contains model weights and inference assets without optimizer or training state. Available weights or code do not establish plug-and-play robot compatibility. Check the required configuration, data and interfaces in the source documentation.

Deployment and usage resources

Architecture and inputs / outputs

Released
November 25, 2026

Scope and training

The tracked wrist point lies on the arm mounting face. Each step outputs that point’s position, wrist rotation (rot6d) and 22 finger values. Quantile statistics for indices 0–8 were recomputed. The origin and axes of the external reference frame remain unconfirmed.

31 DoF · horizon 10 · quantiles

Record identity

Third-party fine-tune

Lineage

Fine-tuned from: π₀ · π₀.₅ ↗

  • Record identity · Lineage · π₀.₅: Dexverse-CSI
  • Record identity · Lineage · π₀.₅: Dexverse-CSI
  • The tracked wrist point lies on the arm mounting face. Each step outputs that point’s position, wrist rotation (rot6d) and 22 finger values. Quantile statistics for indices 0–8 were recomputed. The origin and axes of the external reference frame remain unconfirmed. · continuous: Dexverse-CSI
  • The tracked wrist point lies on the arm mounting face. Each step outputs that point’s position, wrist rotation (rot6d) and 22 finger values. Quantile statistics for indices 0–8 were recomputed. The origin and axes of the external reference frame remain unconfirmed. · continuous: Dexverse-CSI

Related robots

Full parameters and verification notes (model card)

The LeRobot 0.4.4 PI05Policy reuses the data, prompts, cameras and training recipe from the earlier single-arm xlvla run.

Training covers Allegro, Inspire, LEAP, Shadow, Sharpa and Wuji on GraspBleach, GraspPan, GraspKettle and FunctionalHammerStrike, with 1,200 episodes and 325,776 frames. Inputs are task text, base and wrist RGB images, and a 31-dimensional state. The two 480×640 streams are resized with padding to 224×224. The right-wrist slot is masked. State and action contain 3 wrist position values, 6 rotation values (rot6d) and 22 finger values, padded to 32 internally. Indices 0–8 are replaced and their quantile-normalization statistics recomputed. Action chunks contain 10 steps. Use the matching preprocessor, postprocessor and bundled tokenizer for inference.

Submit a source or correction