RobotiqTSF-140
Price
Price not disclosed
Type
Components · Tactile sensors
Status
Commercial
Availability
Not disclosed
Purchase
Release Date
Unknown
Country/Region
Canada
- Physical taxels
- 28 per fingertip
- Signal frequency · pressure
- 60 Hz
- Signal frequency · vibration
- 1000 Hz
- Signal frequency · imu
- 1000 Hz
Robotiq’s TSF-140 replaces the standard fingertips on a fourth-generation 2F-140 gripper. Each fingertip uses a 4 × 7 capacitive array to capture normal-force distribution at 60 Hz and provides vibration and inertial data at 1 kHz. A USB hub connects the sensors to a PC.

Technical specifications
Sensing capabilities and principle
Direct sensing
Normal-force distribution
Direct sensing
Vibration
Direct sensing
Acceleration and angular velocity
Sensing method
4 columns × 7 rows per fingertip; raw unitless CDC counts
Sensing principle
Capacitive
Measurement performance
Other measurement range
Accelerometer ±2 g
Other measurement range
Gyroscope ±250 °/s
Other measurement range
Vibration channel raw range ±32767
Signal frequency · Pressure
60 Hz
Signal frequency · Vibration
1000 Hz
Signal frequency · imu
1000 Hz
Structure and dimensions
Mounting position
Gripper
Physical form
Fingertip module
Physical taxels
28 per fingertip
Sensing layout
Discrete array
Output and communication
Communication interface
USB 2
Connector
USB-A (hub to host PC)
Data output
Unitless CDC counts
Sensing and data flow
Communication frame rate
1000 Hz
Other technical parameters
Record type
Sensor hardware
Other technical parameter
Hardware 2.2, serial pattern 22XXXX
Other technical parameter
Pad surface to mounting screw: 17.9 mm
Other technical parameter
Starter Kit · AGC-TIP-TSF-140-STARTER-KIT
Other technical parameter
Replacement Kit · AGC-TIP-TSF-140
Other technical parameter
Starter Kit: two fingertips, four Ø2 × 6 mm dowel pins, two M5-0.8 × 12 mm socket-head screws, two M2-0.4 × 4 mm Phillips screws, one hub and one USB cable
Other technical parameter
Replacement Kit: two fingertips, four Ø2 × 6 mm dowel pins and two M5-0.8 × 12 mm socket-head screws
Other technical parameter
Longer flat cable and housing with an extended non-sensing section
Mechanical and mounting
Depth
1.09 cm
Height
6.55 cm
Mounting interface
Robotiq 2F-140 V4 (140-V4), gripper serial C-XXXXX
Width
3.05 cm
Communication and control
Calibration method
Per-taxel unloaded offset and periodic sensitivity calibration
Battery and Runtime
Power Supply
USB power via hub
Reliability and environment
Operating humidity
20–80 %RH
Operating temperature
0–40 °C
Commercial Status
Status
Commercial
Price
Price not disclosed
Release Date
Unknown
Submit a source or correction