RobotiqTSF-85
Price
Unknown
Type
Components · Tactile sensors
Status
Unknown
Availability
Not disclosed
Purchase
Not disclosed
Release Date
Unknown
Country/Region
Canada
- Physical taxels
- 28 per fingertip
- Signal frequency · vibration
- 1000 Hz
- Signal frequency · pressure
- 60 Hz

Technical specifications
Sensing capabilities and principle
Direct sensing
Pressure distribution
Direct sensing
Vibration
Sensing method
Pressure array reported in capacitance-to-digital converter counts
Sensing principle
Capacitive sensing
Measurement performance
Other measurement range
Gyroscope full scale: ±250 °/s
Other measurement range
Accelerometer full scale: ±2 g
Signal frequency · Vibration
1000 Hz
Signal frequency · Pressure
60 Hz
Reliability
Typical 1 s noise SD: 0.5 N (50 counts) summed; 8 counts per taxel
Structure and dimensions
Mounting position
2F-85 gripper
Physical taxels
28 per fingertip
Sensing layout
Discrete 4 × 7 array per fingertip
Output and communication
Connector
USB-A (hub-to-host)
Other technical parameters
Record type
Sensor hardware
Other technical parameter
Operating: 0–40 °C; 20–80% RH
Commercial Status
Status
Unknown
Price
Unknown
Release Date
Unknown
Submit a source or correction