HEBI RoboticsH25-90
H-Series 101:1 actuator.
- Output torque · Continuous
- 90 N·m
- Output speed · Maximum
- 50 rpm
The H25-90 is a HEBI H-Series modular robotic actuator with a 101:1 harmonic reduction. It combines a brushless motor, encoders and control electronics in an IP65-designed housing for high-torque custom robot joints.
Technical specifications
Output & transmission
- Output torque · Continuous
90 N·m
- Output torque · Peak
180 N·m
- Output speed · Maximum
50 rpm
Model-level records · configuration applicability unverified
- Development access
- Conditional support
- Actuator technology
- Modular robotic actuator
- Ingress Protection (IP)
- Designed for IP65
- Depth
- 11.4 cm
- Length
- 12.6 cm
- Weight
- 2.9 kg
- Width
- 11.5 cm
- Gear Ratio
- 101:1
- Operating voltage
- 24–48 V
- Emergency Stop
- M-Stop line input, 5–48 V DC
- Operating humidity
- 0–90
- Operating temperature
- -10–50 °C
- Safety System
- Optional brake, locked on power-off
Source · 2
2026-09-24 · 2026-11-06
Output speed · Max Speed · 50 RPM · 2, Technical specifications
Output torque · Cont. Torque · 90 N-m · 2, Technical specifications
Output torque · Peak Torque · 180 N-m · 2, Technical specifications
Development access · H25-90 appears in the series configuration table; series datasheet explicitly documents C/C++ and Python APIs.
Actuator technology · Modular robotic actuator
Ingress Protection (IP) · Designed for IP65
Depth · 11.4 cm
Length · 12.6 cm
Weight · 2.9 kg
Width · 11.5 cm
Operating voltage · 24–48 V
Emergency Stop · M-Stop line input, 5–48 V DC
Operating temperature · -10–50 °C
Safety System · Optional brake, locked on power-off
Compare family models
Choose 2–4 configurations
Compare selected configurationsDevelopment support
H25-140
Conditional accessH25-140 is explicitly listed in the official series datasheet with C/C++ and Python API support. Use compatible module firmware, matching API distribution, Ethernet discovery, exact family/name, calibrated actuator limits and model-specific gains. The reviewed native profile uses strategy 5 (FOC). H-Series motor torque feedback is current-based; this is not independent output strain-gauge torque measurement.
H25-90Current model
Conditional accessH25-90 is explicitly listed in the official series datasheet with C/C++ and Python API support. Use compatible module firmware, matching API distribution, Ethernet discovery, exact family/name, calibrated actuator limits and model-specific gains. The reviewed native profile uses strategy 5 (FOC). H-Series motor torque feedback is current-based; this is not independent output strain-gauge torque measurement.
H25-45
Conditional accessH25-45 is explicitly listed in the official series datasheet with C/C++ and Python API support. Use compatible module firmware, matching API distribution, Ethernet discovery, exact family/name, calibrated actuator limits and model-specific gains. The reviewed native profile uses strategy 5 (FOC). H-Series motor torque feedback is current-based; this is not independent output strain-gauge torque measurement.
H25-90 is explicitly listed in the official series datasheet with C/C++ and Python API support. Use compatible module firmware, matching API distribution, Ethernet discovery, exact family/name, calibrated actuator limits and model-specific gains. The reviewed native profile uses strategy 5 (FOC). H-Series motor torque feedback is current-based; this is not independent output strain-gauge torque measurement.
Development capabilities
Each rotary module accepts joint-level position, velocity and effort commands through the discovered Group; radians, rad/s and N m apply in this strategy. This standalone actuator is not a complete arm or Cartesian controller.
Real Group command/feedback logging uses start_log/stop_log or C++ startLog/stopLog and .hebilog at the configured feedback frequency. Check log creation and directory permissions; Python log rollover may need a background thread. This is raw module telemetry, not an annotated multimodal demonstration dataset.
Pinned Python examples use hebi-py >=2.2.0, Python3 and GroupCommand.position/velocity/effort. Match the installed API/firmware and exact module identity; Python2 is excluded.
Pinned examples use native C++ GroupCommand and fetch hebi-cpp 3.15.0 with a fixed distribution checksum. Dependencies and matching firmware are required; no build or hardware execution is claimed.
GroupCommand.setPosition/position commands a rotary joint angle in radians with the matching position controller/gains enabled. It is an instantaneous setpoint; build and refresh trajectories separately.
The dedicated velocity example sets GroupCommand velocity in rad/s without a position target. Clear prior position commands with NaN and configure the velocity controller for the selected strategy; this is not merely a speed limit.
The combined position/velocity/effort example adds acceleration*inertia effort while tracking position and velocity. Strategy 5 (FOC) accepts additional user effort in N m; tune model-specific gains/inertia. It is not proof of whole-arm gravity compensation accuracy.
The dedicated effort example sends N m torque without position/velocity targets. Clear both previous targets using NaN and select strategy 5 (FOC). DIRECT_PWM normalized duty and direct FOC current/voltage are different modes. H-Series motor torque feedback is current-based; this is not independent output strain-gauge torque measurement.
Documented constraints
- H25-90 is explicitly listed in the official series datasheet with C/C++ and Python API support. Use compatible module firmware, matching API distribution, Ethernet discovery, exact family/name, calibrated actuator limits and model-specific gains. The reviewed native profile uses strategy 5 (FOC). H-Series motor torque feedback is current-based; this is not independent output strain-gauge torque measurement. Position/velocity targets are rad/rad/s and rotary effort is N m only in the selected control strategy. Clear stale targets explicitly with NaN; an empty command may retain setpoints, and zero effort actively requests zero torque rather than disabling control. Refresh commands within configured command lifetime (publisher default 250ms); do not treat this as a motion-performance guarantee. Persist required strategy/gain settings deliberately across reboot. H default strategy5 differs from X/R strategy4. Examples use one test module and hardcoded names; adapt identities, not firmware modes blindly. Example-code licensing excludes binary APIs/dependencies/firmware/hardware. No exact 4DoF arm-kit integration is inferred.
Sources · 9
- Officialdocs.hebi.us ↗Verified: 2026-11-06
- Officialraw.githubusercontent.com ↗Verified: 2026-11-06
- Officialdocs.hebi.us ↗Verified: 2026-11-06
- Officialraw.githubusercontent.com ↗Verified: 2026-11-06
- Officialraw.githubusercontent.com ↗Verified: 2026-11-06
- Officialraw.githubusercontent.com ↗Verified: 2026-11-06
- Officialraw.githubusercontent.com ↗Verified: 2026-11-06
- Officialraw.githubusercontent.com ↗Verified: 2026-11-06
- Officialdocs.hebi.us ↗Verified: 2026-11-06
Open source & build resources
Software
Partially availableExamples or supporting tools are available; this does not establish access to the core system.
Hardware design
Partial hardware documentationOfficial H-Series documentation covers H25-45, H25-90 and H25-140 and links dimensional drawings, collar clamps, adapters and arm-link CAD. It also explains power, fiber Ethernet and M-Stop wiring. These are partial integration materials; complete actuator manufacturing files and hardware licensing have not been verified.
View explanationBuild resources
Not verifiedThere is not enough verified evidence to establish this dimension.
| Type | Resource | License | Applicable version | Open |
|---|---|---|---|---|
| Code | HEBI native C++ examples · pinned Apache-2.0 primary code GitHub · HebiRobotics/hebi-cpp-examples The reviewed Apache-2.0 grant covers the primary example-project code at this commit. Downloaded C++ API wrapper/C binary distribution, dependencies, Python examples, firmware, actuator hardware and complete robot kits have separate licensing/access scope. | Apache-2.0 | hebi_h25_90_native_group_command | Open GitHub |
| Hardware | HEBI H25 CAD, mounting and wiring references docs.hebi.us Official H-Series documentation covers H25-45, H25-90 and H25-140 and links dimensional drawings, collar clamps, adapters and arm-link CAD. It also explains power, fiber Ethernet and M-Stop wiring. These are partial integration materials; complete actuator manufacturing files and hardware licensing have not been verified. | — | H25-90 | Open documentation |
| Tool | H25-90 Strategy 5 gain configuration docs.hebi.us Official downloadable XML starting gains for H25-90. H-Series supports Strategy 5; tune gains for the actual mechanism and application using the manufacturer's guidance. This is a configuration file, not actuator firmware source or a robot manufacturing package. License permissions have not been verified. | — | H25-90 | Open documentation |