Price
Unknown
Type
Components · Tactile sensors
Status
Research prototype
Availability
Not disclosed
Purchase
Not disclosed
Release Date
Unknown
Country/Region
United States

DenseTact 2.0 is an optical tactile fingertip prototype from Stanford ARMLab. LEDs illuminate a patterned silicone hemisphere while a camera observes its deformation. The sensor reconstructs the 3D contact shape and estimates three force and three torque components. It was demonstrated on an eight-degree-of-freedom gripper.

DenseTact 2.0

Technical specifications

Sensing capabilities and principle

Derived capabilities
3D contact shape reconstruction
Derived capabilities
Six-axis wrench estimation (three force and three torque components)
Direct sensing
Gel surface deformation
Sensing method
Camera imaging of deformation in LED-lit, randomly patterned silicone
Sensing principle
Optical imaging

Structure and dimensions

Mounting position
Gripper fingertip
Physical form
Tactile fingertip
Sensing layout
Continuous hemispherical surface

Output and communication

Data output
RGB images

Related entities and public cases

Papers and research projects
Calibration reference: indenter and holder STL files, training/test indexes
Papers and research projects
Paper researchers: Won Kyung Do, Bianca Jurewicz, Monroe Kennedy III

Other technical parameters

Record type
Research prototype
Other technical parameter
Housing dimensions include the camera module
Other technical parameter
Hemispherical gel diameter: 31.5 mm
Other technical parameter
Gel hardness: 49.7 Shore OO
Other technical parameter
Camera module: 30 fps
Other technical parameter
Acquired image: 1024 × 768
Other technical parameter
Cropped model input: 640 × 640
Other technical parameter
M12 lens, 185° field of view
Other technical parameter
Franka loading arm and ATI Gamma SI-65-5 reference
Other technical parameter
Mean absolute shape error on the DenseNet hold-out set: 0.3633 mm
Other technical parameter
Mean absolute force error on the DenseNet hold-out set: about 0.410 N
Other technical parameter
Mean absolute torque error on the DenseNet hold-out set: 0.387 N·mm
Other technical parameter
Calibration dataset: Fx/Fy ±5.5 N, Fz −11 to +3 N
Other technical parameter
Calibration dataset: Tx/Ty ±0.25 N·m, Tz ±0.05 N·m
Other technical parameter
Demonstrated on an eight-degree-of-freedom research gripper
Other technical parameter
Depth ground-truth encoding: 0.0182 mm per grayscale step

Physical Specifications

Materials
Patterned silicone elastomer

Mechanical and mounting

Depth
3.2 cm
Height
4.3 cm
Weight
0.034 kg
Width
3.2 cm

Sensors

Camera
Sony IMX179
Lighting (sensing)
Internal LED strip

Commercial Status

Status
Research prototype
Price
Unknown
Release Date
Unknown

Video

Submit a source or correction